Biofilter Systems - bioteg GmbH -> HomeBiofilter Systems - bioteg GmbH Biofilter Systems - bioteg GmbH -> ContactBiofilter Systems - bioteg GmbH Biofilter Systems - bioteg GmbH -> SolutionsBiofilter Systems - bioteg GmbH Biofilter Systems - bioteg GmbH -> InformationBiofilter Systems - bioteg GmbH Biofilter Systems - bioteg GmbH -> DistributionBiofilter Systems - bioteg GmbH Biofilter Systems - bioteg GmbH -> References Biofilter Systems - bioteg GmbH

Biofilter Systems - References

page 1 2 3 [4]


Project: sludge dewatering facility
Location: Backnang, Germany
System: MCBF 6000 QSW GSW, NH3 scrubber
Application: off-gas from sludge dewatering
Contaminants: NH3 5,000 vpm, 70,000 OU/m³
Removal: OU/m³ ≤ 300
Airflow rate: 6,000 m³/h
Footprint: overall 10.5 m x 8.5 m
Installed in: January 2002

Project: Stadtentwässerung Hamburg
Location: Hamburg, Germany
System: SRBF 300 OBR
Application: waste water pump station
Contaminants: H2S, sludge odors
Removal: no odor nuisance to neighbors
Airflow rate: 300 m³/h
Footprint: 2.0 m x 2.0 m
Installed in: November 2001

Project: Community Stams
Location: Stams, Austria
System: SRBF 400 OBR under ground
Application: pump station
Contaminants: H2S, waste water odors
Removal: no odor nuisance to neighbors
Airflow rate: 300 m³/h
Footprint: 2.0 m x 2.0 m
Installed in: October 2002

Project: WWTP Szob
Location: Szob, Hungary
System: MCBF 300 QSW, integrated scrubber
Application: WWTP
Contaminants: H2S, sludge odors
Removal: OU/m³ ≤ 400
Airflow rate: 3,400 m³/h
Footprint: 12.2 m x 2.2 m
Installed in: January 2003

Project: IFK Berlin
Location: Berlin, Germany
System: Scrubber GSW 1500, 2 units special construction
Application: research institute
Contaminants: white and red phosphor dust
Removal:
Airflow rate: 1,500 m³/h
Footprint: 1.4 m x 1.4 m
Installed in: November 2002 (1st unit)
May 2003 (2nd unit)
March 2004 (3rd unit)

Project: Grossfurtner
Location: Ried am Inn, Austria
System: MCBF 500 QSW, MCBF 1000 QSW
Application: Meat Factory
Contaminants: odors from production wastes
Removal: no odor nuisance to neighbors
Airflow rate: 500 m³/h, 1000 m³/h
Footprint: 4.8 m x 2.8 m
Installed in: September 2003: MCBF 500 QSW
March 2004: MCBF 1000 QSW

page 1 2 3 [4]

 